Please read entire page before placing an order.This new
OEM circuit board is for replacing Balboa 54385 circuit boards having a VS511SZR2(x) chip number.
The Balboa 54385 VS511SZR2(x) circuit boards are also found in hot tubs made by Hydro-Quip, Inc. under the part number 33-0033-K.
Tip: The "(x)" shown above is shorthand for a range of last letters on VS511SZR2 chip numbers this circuit board can replace.
Please note: A list of chip numbers this circuit board can replace is specified in the
CROSS REFERENCE VERIFICATION section below.
Please Note: The numbers on the new circuit board you receive may be different and the components may look slightly different but it will still connect the same and it is a fully compatible
OEM replacement .
Tip: When replacing a hot tub circuit board, testing the heater and replacing it (if bad), is recommended before installing or applying voltage on a new circuit board.
Note: A continuity test is not a sufficient heater test. Contact us by phone for more details on testing a heater.
See
RELATED PRODUCTS below for heater replacements.
Tip: Burned circuit boards or burned heater relays are often due to a loose electrical connection or a bad heater or both.
If all connections are tight and if the heater is good then the heater relays are probably old and worn out.
If a burned relay was powering a pump and all electrical connections are tight then the relay is probably old and worn out or the pump might be bad or going bad or all three.
Replacing the heater and/or pump with a new one is recommended if any of those scenarios apply.
Tip: Items shown in
RELATED PRODUCTS below have also been found in hot tub systems with Balboa 54385 VS511SZR2(x) circuit boards.
Unsure of what something on this page means?
Please contact us so we can better assist you.